DW – KL50: Twin wall insulated, factory-made exhaust system with special conical metal to metal jointing for high temperatures and high pressures.
DW – FS50: The DW FS system of Jeremias is a twin wall insulated, factory made exhaust system with flanged connection and with graphite gasket between flanges, that guarantees the tightness for high…
Enquire with us today
Product information
Engineered for extreme performance in mission-critical environments
Jeremias UK offers two high-performance twin-wall flue systems—DW KL 50 and DW FS—designed to meet the most demanding requirements of high-temperature and high-pressure exhaust applications. These systems are the preferred choice for backup generator sets in data centres, mission-critical infrastructure, and industrial energy systems, where reliability, pressure integrity, and thermal resistance are non-negotiable.
Both systems are available with custom insulation thicknesses (typically 32 mm or 50 mm) and a wide range of inner and outer liner material combinations (AISI 304 or AISI 316L), allowing full adaptability to project-specific needs.
| DW-KL 50 | DW-FS 50 | |
|---|---|---|
| MATERIAL | Inner wall: AISI 304 – Optional AISI 316 Outer wall: AISI 304 |
Inner wall: AISI 316L – Optional AISI 304 Outer wall: AISI 304 |
| INSULATION | High density rigid rockwool (120 kg/m3) | High density rigid rockwool (120 kg/m3) |
| WORKING TEMPERATURE | ||
| FINISHING | Standard: Bright annealed (BA) RAL colours (Check prices) Optional outer wall: Galvanised steel -15% (only lengths and deviations) |
Standard: Bright annealed (BA) RAL colours (Check prices) Optional outer wall: Galvanised -15% (only lengths and deviations) |
| THICKNESS | Inner wall: 0,4 – 0,5 – 0,6 (depending on the diameter) Insulation: 50 mm Outer wall: 0,4 – 0,5 – 0,6 (depending on the diameter) |
Inner wall: 0,6 – 0,8 (depending on the diameter) Insulation: 50 mm Outer wall: 0,5 – 0,6 – 0,8 (depending on the diameter) |
| AVAILABLE DIAMETERS (mm) | Ø150 a Ø800 | Ø130 a Ø800 |
| CONNECTION SYSTEMS | Male-female push fit connection secured by locking band (2.0) included | Flanged connection inside with V-band secured with ceramic wool and externa locking band 2.0. |
| FIRE RESISTANCE | ||
| CE CERTIFICATE | 0036 CPR 9174 061 | 0036 CPR 9174 086 |
| EC CLASSIFICATIONS (UNE-EN 1856-1) | T600 – N1 – D – Vm – L20040 – G(70) T600 – H1 – W – Vm – L20040 – O(50) T200 – H1 – W – Vm – L20040 – O(20) T200 – P1 – W – Vm – L20040 – O(00) |